Top navigation bar for CareBase power quality website, homepage and product specification pages focused on mission-critical power systems protection, battery backup, precision voltage regulation and redundant on-line UPS using automatic transfer switches.

The latest news and product announcements. Power/surge protection, conditioning, control, battery backup and voltage regulation products. White Papers-Articles On Understanding and Achieving High Availability & High Quality Power Double Conversion True On-Line Battery Backup - Uninterruptible Power Systems & Single Conversion UPS Outdoor UPS for Extreme Temperature/Weather Environmental Conditions In Exterior Rated NEMA Enclosures AC Automatic Transfer Switches For Redundant Power Sources or UPS Bypass AC Power Conditioners - Low-Impedance Isolation Transformer and Ferroresonant Transformers Left navigation bar for the CareBase website focusing on mission-critical power systems and surge protection, utilizing UPS, precision automatic voltage regulators, line conditioners, battery backups, automatic transfer switches, on-line outdoor UPS, surge protective devices and more.
 

CareBase
TM
 


 

Dc to Ac Inverters 

rack-mountable with transformer isolation and pure sine wave output

 Dc to ac inverter, 24V/24vac to 115V/115vac (120V/120vac) with transformer isolation and voltage regulation, rack-mountable

Click here for complete specifications in a
printer friendly Adobe Acrobat PDF format
 XINv Series
 +/- 24vdc to 115vac
 600VA and 900VA
These heavy-duty XINv Series dc to ac inverters are housed in a 2U rack-mountable enclosure. XINv PWM inverters feature a transformer isolated sine wave output. They are designed for all applications requiring continuous pure sine wave power. The models on this page produce 115 volts ac (or 110V or 120V) from +/-24 volts dc.

Typical XINv series applications
Applications include all waveshape sensitive equipment such as telecommunications systems, industrial, measurement and other mission-critical, harmonic-sensitive electronics. They are also ideal for use in facilities with 24 vdc rectifier/battery power plants, where the inverter can be used to provide the function of a double-conversion on-line UPS.

Key XINv series benefits
XINv uses high-performance microprocessor and unipolar pulse-width-modulated (PWM) power conversion circuits for high efficiency and low input dc ripple currents. They also feature high dc to ac power conversion efficiency, pure sine wave output and long MTBF. XINv also provides precision automatic voltage regulation with 115vac +/-3% and less than 5% THD. XINv’s 2U high construction with optional wall or rack-mounting kits provides maximum flexibility for telecom and industrial users. XINv offers a hardwire terminal block battery connection with a dc circuit breaker for external 24vdc battery banks.

How the XINv series works
A rugged, high-performance microprocessor and unipolar pulse-width-modulated (PWM) power conversion circuit takes the dc input and converts it into a pure sine wave. The circuitry automatically adjusts the duty cycle of the output for all loads and inputs. XINv delivers a stable 60Hz +/-0.5% frequency. A dc circuit breaker protects all dc circuits, and an overload shutdown feature protects the inverter from overload. If the input dc voltage drops below 21 vdc, a DB9 connector in the rear of the inverter sends signals for inverter output failure and low dc input voltage. A comprehensive array of output current, battery charge levels, and status LED indicators are provided for visual assessment of inverter status. A DB-9 port is provided for communication using RS-232 or dry relay contact signals.


Key XINv features
Pure sine wave output
Eight NEMA 5-15R receptacles
Rack or wall mountable with optional rack/wall-mount kits
Unipolar PWM inverter
Ac output is isolated from dc
Rugged construction supports mobile and portable applications

 

+/-3% voltage regulation
Comprehensive array of status LEDs/bargraphs
SNMP compatible via RS-232 port with optional SNMP adapter
Both RS-232 and relay contact signals are provided
Two year limited warranty parts and labor

 

   Specifications XINv-600-24V XINv-900-24V
    Electrical

 

   Capacity in VA (watts) 600VA (600W) 900VA (900W)
     Inverter type Pulsed-width-modulated (PWM) with isolation transformer.
    Input
     Nominal voltage -24 volts dc or +24 volts dc
     Operating voltage 21 to 29 volts dc
     Maximum input current 35 amperes 50 amperes
     Dc input connector 3 screw terminal blocks for earth ground, (+), (-) dc inputs
     Recommended wire size  10mm2 (8 AWG) 15mm2 (6 AWG)
    Output
     Ac output voltage 115 volts +/-3% ac (factory settable to 110 vac or 120 vac)
     Frequency stability 60 Hz +/-0.5%
     Output waveform  Pure sine wave. Less than 5% maximum THD for 0 to 100% loads.
     Load compatibility All linear and non-linear loads from -0.6 (leading) to +0.6 (lagging) power factor, including new power-factor corrected switchmode power supplies & older non-power-factor corrected power supplies.
     Load crest factor Up to 3:1 crest factor loads can be powered by the inverter.
     Surge current capability Up to 300% surge power is available to power load equipment
with high starting/stopping surge currents for a few ac cycles.
     Overload capability 1 minute @ 120% overcurrent.
     Power efficiency Greater than 85% under all load and dc input voltage conditions.
     Power on/off switch Recessed on/off rocker style power switch.
     Isolation and grounding     100% isolation between input dc and output ac
(isolation transformer included). Metal enclosure is
bonded to dc input terminal block earth ground input.
     Audible noise 45 dBA @ 1.5m
     Ac receptacles Eight standard NEMA 5-15R female receptacles.
    Status indicators and communications
     Status Indicators

   Dc input voltage indicator: 5 green LEDs (20% per each LED).
   Ac output current: 5 green LEDs (20% per each LED).
   Inverter On: 1 yellow LED illuminates during normal operation.
   Overload: 1 red LED illuminates if overload condition exists.

     Communications Rear-mounted DB-9 female signal port.
(For DB9, RS-232C serial communications and optional SNMP interface information, please see this unit's specifications PDF)
    Physical
     Dimensions 406mm(16")wide x 381mm(15")high x 89mm(3.5")deep (2U high)
     Weight 12 kg(26 lbs) 18 kg(38 lbs)
     Rack or wall mounting kits
   (optional)
   23"/24" also available
For standard 19" cabinet: use front pair # MK-5019A
For telecom center-mount rack: use center pair # MK-5019F
For wall or floor mount kit: MK5000C
    Safety
    Agency approvals Designed to meet IEC 60950 safety standards.
     Dc breaker Protection against shorts or misapplication of inverter current.
    Low voltage disconnect Inverter turns off automatically if input voltage drops below 21vdc.
     Overload shutdown Inverter turns off automatically if overload is >120% over 1 minute.
    Environmental
     Ambient temperature -20° to +40°C (-4° to +104°F), 5 to 95% relative humidity
(non-condensing). Storage temp. -20
° to +60°C(-4° to +140°F)
     Cooling Method Forced air (internal hot air exhaust fan is included.
     Elevation 0 to 4000 meters (0 to 12,400 feet) above sea level.
    Warranty
     Warranty 2 year limited depot warranty, parts and labor.
TSi's ongoing product improvement process makes specifications subject 
to change. Other companies product names herein are for identification purposes only, and may be trademarks of their respective companies. 

XINv dc to ac inverter front view

      Front view of system status indicator lights/LEDs showing on/off switch, output current level, inverter on/off, overload condition, dc input voltage, XINv Series rack-mountable dc to ac inverter with precision automatic voltage regulation, isolation transformer and neutral-ground bond.

XINv dc to ac inverter rear view

      Rear view of system, showing dc input circuit breaker, dc input terminals, DB-9 communications port, RS-232 and relays alarm contact signals or SNMP using optional adapter, ac output via eight standard NEMA 5-15R receptacles, XINv Series rack-mountable dc to ac inverter with precision automatic voltage regulation, isolation transformer and neutral-ground bond.

XINv system architecture diagram

XINv system architecture drawing showing 24vdc input circuit breaker, dc input terminals, DB-9 communications port, RS-232 and relays alarm contact signals or SNMP using optional adapter, ac output of 115V +/-3%, neutral-ground bond on isolation transformer output, XINv Series rack-mountable dc to ac inverter with precision automatic voltage regulation, isolation transformer and neutral-ground bond.

TSi Power also manufactures custom dc to ac inverters. For special applications, please call. 

Back to top

 

                                               CareBase ~ PO Box 2987 ~ Glenwood Springs, Colorado  81602-2987 ~ USA ~ +1 970 945 2770 ~ 800.430.2770 (USA/CAN)
                                                   Please e-mail michael.gibson@carebase.com re: questions, RFQs, applications, etc. Copyright 1988- 2006 CareBase
                                                                                                                                  Hit Counter