| The
ILc-VRp dual range automatic precision voltage regulator with built-in
low-impedance isolation transformer allows trouble-free operation of
electronic equipment over a very wide ac voltage range of 120V or 240V
+/-20% found in many developing countries. Output regulation responds in
less than one line cycle and corrects output voltage to +/-2.5% with
20,000 corrections per second. There is no switching of taps or otherwise
a break in the power path as continuous PWM (pulse-width-modulation)
switching of the primary winding of a buck-boost transformer leaves the
secondary power path intact. Typical ILc-VRp
applications
Designed for applications where
absolutely safe and precisely regulated ac power is required, such as
mobile telecommunications, wireless, satellite and carrier equipment.
Key ILc-2000-VRp-Dual-Range
system benefits
The lightweight, high efficiency dual voltage range ILc-VRp is easy to
install in indoor environments. The unit comes in a rack-mountable
enclosure and has the ability to accept either 120 vac or 240 vac +/-20%
input via either a IEC 320 C-20 input connector for the 120vac, or an
IEC 320C-13 inlet connector for the 240 vac. Power output is up to
1800 watts, and can be drawn from Either/or Both 115 vac and 230 vac
+/-2.5%, as long as total output power is not exceeded. 115 vac and 230
vac outputs are provided via two standard NEMA 5-15R receptacles for the
115 vac, and one UK BS1363 outlet connector for the 230 vac. The
automatic bypass assures that connected equipment will not shut down,
even if the ILc-VRp unit were to fail. The ILc-VRp is compatible with
all loads as it does not switch any components in the power path.
ILc-VRp’s ultra-low impedance assures stability even with the most
demanding loads. The isolation line conditioner components provide
maximum equipment protection against surges, spikes and transients, for
higher equipment reliability and maximum equipment operating life. In
addition, improved repeatability, fewer reboots or system lock-ups.
Also, a reduction in equipment down time and service costs can be
expected. Maximum transformer and regulator performance, reliability and
lifetime is achieved by a design with no moving mechanical parts other
than a thermostatically controlled high reliability cooling fan to
control the unit’s internal temperature.
How the ILc-VRp
2000VA dual range system works
The ILc-VRp unit is comprised of an automatic precision voltage
regulator, and an isolation line conditioner. Unit has a front panel key
switch to select either 120 vac or 240 vac, with a safety interlock to
prevent voltage from appearing on unused terminals. The high frequency
IGBT driven converter microprocessor takes the incoming ac power,
measures against the nominal voltage and adds or subtracts voltage,
20,000 times per second, to achieve precisely regulated 230 or 120 vac
output, cycle by cycle. Voltage correction times do not exceed 1 cycle,
or 20 milliseconds for all mains ac voltage changes, even for
instantaneous voltage changes from 96 to 144 vac (when at the 120 vac
input setting) or from 192 to 288 vac (when at the 240 vac input
setting). The ILc-VRp starts on sine wave zero voltage crossing point
upon turn-on. This reduces potentially damaging inrush currents into
difficult loads. The automatic bypass will be activated when there is a
fault condition, and makes operation possible without regulation. Three
LEDs display unit status, the Green LED indicates Normal (regulating
protected mode operation), Yellow LED indicates Bypass (non-regulated
output), and the Red LED indicates a Fault condition. (If Green LED is
off, it means internal circuit board needs replacement). A low-impedance
isolation transformer provides complete isolation between the primary
and secondary, and permits bonding its output neutral to ground, which
completely eliminates all disturbances between neutral and ground. The
leakage inductance of the isolation transformers, in combination with
capacitive elements and MOVs, provide superb noise filtering, as well as
coordinated multi-stage surge protection in accordance with the
principles of IEC-61312. |
| |
SPECIFICATIONS |
ILc-2000-VRp-Dual-Range |
| |
Electrical |
|
Capacity in VA (watts) |
2 kVA (2kW) |
| |
Transformer type |
Isolation transformer with
key-switched taps
for dual range capability. |
|
Regulator engine |
High frequency 20 kHz IGBT driven voltage
regulation converter. Pulse-width-modulated ac to dc converter and dc to
ac topology. |
| |
Input |
| |
Nominal voltage |
120
or 240 volts ac (user selectable via key switch with safety interlock to
prevent voltage from appearing on the unused terminals). |
| |
Normal operating range |
120
or 240 vac +/- 20%.
Short duration (less than 5 minutes) operation +/- 30%. |
| |
Nominal frequency |
47 to 63 Hz |
| |
Input circuit breaker |
Circuit breaker with 150% overload
capability for heavy start load. |
| |
Circuit breaker rating |
20
amperes @ 120 vac or 10 amperes @ 240 vac |
| |
Input |
120 vac IEC 320 C-20 inlet. 240 vac IEC 320
C-13 inlet. |
| |
Output |
| |
Nominal voltage |
115 vac and/or 230 vac |
| |
Power efficiency |
Better than 96% |
| |
Voltage regulation |
115 vac +/-2.5%, or 230 vac +/-2.5% |
| |
Automatic bypass |
Automatic bypass will be activated when
there is a fault condition. |
| |
Safe start |
Unit starts on sine wave zero voltage
crossing point upon turn-on.
Unit is fully functional/regulated within 5 seconds of mains
restoration. |
| |
System status indicators
(per phase) |
System status LEDs
provided as follows:
Green LED (blinking) indicates Normal (regulating mode operation),
Yellow LED (blinking) indicates Bypass (non-regulated output),
Red LED indicates Overload (system may shut down). |
| |
Surge protection |
A
three stage surge protection system consisting of
isolation transformer, capacitor and MOV is included |
| |
Surge test conditions |
Class 2 & Class 3 simulated lightning surge (Combination wave) per
ANSI/IEEE C62.41-1991, Cat. C test waveform: 6kV, 3kA, 8x20µs. |
| |
Surge let-through voltages
(system will continue
to operate without
interruption under
these conditions) |
Single
Pulse: L-N: 50V, L-G: 50V, N-G: 0.5V
Ring wave: L-N: 20V, L-G: 20V, N-G: 0.5V
Combination Wave: L-N: 250V, L-G: 250V, N-G: 0.5V
The measured rate of voltage
rise/fall (dV/dt of the remnant waveform
is less than 10V/ms
with input test waveform dV/dt of 6kV/ms |
| |
Common mode filtering |
Neutral-ground bond eliminates all noise or
voltage on neutral (<0.5V) |
| |
Normal mode filtering |
A built-in inductor-capacitor filter
attenuates
EMI/RFI noise from output. |
| |
Output receptacles |
Two NEMA 5-15R (120 vac), and one UK BS 1363
(230 vac) socket. |
| |
Physical |
| |
Dimensions |
436mm(17.2")wide x 127mm(5")high x 381mm(15")deep |
| |
Weight |
22.7 kg (50 lbs) |
| |
Rack-mounting (optional) |
For 19" Front mount: MK-8019A. For 19" Rear
mount: MK-8019B. |
| |
Safety |
| |
Standards |
Design ready to meet UL, cUL and EMC
standards. |
| |
Environmental |
| |
Ambient temperature |
-5º
to +35ºC (23º to +95ºC),
90% relative humidity (non-condensing) |
| |
Cooling method |
Fan cooled. |
| |
Warranty |
| |
Warranty |
Two year limited warranty, parts and labor. |
|
TSi's ongoing product
improvement process makes specifications subject to change. Other
companies product names herein are for identification purposes only, and
may be trademarks of their respective companies. |
ILc-2000-VRp
dual range rear view

ILc-2000-VRp
dual range system
architecture
 TSi Power also manufactures
custom (bespoke in the UK) line conditioners.
For special or unusual applications, please call.