| The
TSi Power Outdoor-UPs-8015/8016 with dc output are for dc powered
applications needing backup power in extreme weather conditions. They are
constructed with wide temperature batteries and are housed in a weather
protected IP44(NEMA-3R) enclosure. These offer a wide input voltage window
(88 to 264 vac) and low ripple 12 vdc output, with heavy duty surge
protection and noise filtering.
Typical applications
These heavy duty outdoor UPS systems are designed to power wireless
communications, perimeter surveillance cameras (CCTV), security/gate
control systems, LED traffic light/roadway display systems and industrial
remote terminal units (RTUs).
Key benefits of
the Outdoor UPs-8015/8016
This rugged outdoor dc output UPS design is suitable for use in severe
outdoor environments. Outdoor UPs extreme/wide temperature batteries
allow operation of the UPS system over an ambient temperature range of
-20°to +60°C (- 4° to +140°F); - 40° to +60°C (-40° to +140°F) with
optional battery heater. The wide input voltage window enables dc output
without having to drain or exercise the batteries, thereby ensuring long
battery life. Battery run-times for the Outdoor-UPs-8015 are
approximately 0.4 hour at 96 watts load, and 1 hour at a 48 watts load.
For the Outdoor-UPs-8016, approximately 1 hour at 96 watts load, and 2
hours with a 48 watts load.
How the Outdoor
UPs-8015/8016 works
The outdoor UPs with dc output provides extended battery backup through
a system which takes nominal 115 or 230 vac input (from 88 to 264 vac),
converts it to dc, charges the batteries, and delivers a nominal 12 vdc
(10 to 14 vdc) with a less than 200 millivolts peak to peak ripple. The
heavy duty surge protection and noise filtering on the ac input helps
protect the unit and load from transient surges on the line. Because the
unit is already delivering dc power, upon a deep brownout or loss of
power, the Outdoor UPs with dc output has a zero transfer time to the
reserve power in the batteries. For OEMs, a small ‘hotel’ space is
provided inside the unit for your equipment to reside.
|
| |
Specifications |
Outdoor UPs-8015 |
Outdoor UPs-8016 |
| |
Electrical |
|
Capacity in watts |
96 watts |
| |
UPS type |
Ac to dc rectifier, battery charger and
sealed gel-cell batteries.
|
| |
Input |
| |
Nominal voltage |
115 or 230 volts ac |
| |
Operating voltage |
88 to 264 volts ac without using batteries. |
| |
Input current |
2A maximum @ 115 vac, or 1A maximum at 230
vac. |
| |
Operating frequency |
50 or 60 Hz (47 to 63 Hz) |
| |
Output |
| |
Nominal voltage |
12 volts dc |
| |
Operating voltage |
10 to 14 volts dc (depending on battery
charge status) |
| |
Output current |
8A maximum @ 12 vdc |
| |
Dc ripple voltage |
Less
than 200 millivolts peak to peak |
| |
Power efficiency |
84% (typical) |
| |
Power on/off switch |
On/off rocker style power switch |
| |
Transfer time to backup |
Zero transfer time |
| |
Batteries |
5 amp hours, 12 vdc
10 amp hours, 12 vdc
Wide temperature gel-cells -20º to +60ºC (-4º to +140ºF);
-40º to +60ºC (-40º to +140ºF) with optional battery heater) |
| |
Battery back-up time
|
0.4
hour @ 96 watts (4A) load,
1 hours @ 48 watts (2A) load. |
1 hour @ 96 watts (4A) load,
2 hours @ 48 watts (2A) load. |
| |
Recharge time |
4
hours to 90% capacity
after full discharge. |
18 hours to 90% capacity
after full discharge. |
| |
Ac connections |
3
position terminal block provided for 3 x 1mm2
(18 AWG),
L1, L2 and Ground connections via
12mm (1/2") diameter liquid-tight cable glands. |
| |
Dc connections |
2 position terminal block provided for dc output wires connection
via 19mm (3/4") diameter liquid-tight cable glands. |
| |
Physical |
| |
Dimensions |
254mm(10")wide x 305mm(12")high x
152mm(6")deep |
| |
Weight |
14kg (30 lbs) |
21kg (45 lbs) |
| |
Steel cabinet |
Full weather IP44 (NEMA 3R) UL 50
outdoor padlockable enclosure. |
| |
Mounting options |
Wall mountable via enclosure's top+bottom
brackets.
Pole mountable to monopole via optional 'H' style
bracket (mounting bands not included). Also, optional
pedestal (ground) brackets are available.. |
| |
'Hotel' space for
OEM/integrator option |
Approximately 254mm(10")wide x
76mm(3")high x 152mm(6")deep (if more space is needed, unit can be built
with larger enclosure). |
| |
Environmental |
| |
Operating temperature,
battery heater option |
-20º to +60ºC (-4º to +140ºF), ambient air
temperature,
-40º to +60ºC (-40º to +140ºF) with optional battery heater. |
| |
Warranty |
| |
Warranty |
2 year limited warranty, parts and labor. 1
year battery warranty. |
|
TSi's ongoing product
improvement process makes specifications subject
to change. Other
companies product names herein are for identification purposes only, and
may be trademarks of their respective companies. |
Outdoor UPs-8015/8016
input/output

Outdoor UPs-8015/8016
pole mounting option

TSi Power also manufactures
custom outdoor UPS. For special applications, please call.
Back to top
|