Outdoor UPS
uninterruptible power
supplies for
remote battery
back-up ac or dc power
with
extreme wide temperature batteries |
 |
|
Outdoor UPS, also known as exterior rated uninterruptible power
systems
(UPS systems/battery backups)
are available in standard IP 44 (NEMA 3R) and other enclosures for use in
extreme wide temperature exterior environments to support applications such as: outdoor
surveillance cameras, telecommunications, cellular, wi-fi, base stations and
others.
Outdoor uninterruptible power systems table
| |
Outdoor
UPS features |
Outdoor
UPS series |
Outdoor UPS are for where uptime is critical to an
operation's
mission fulfillment. Typical outdoor UPS back-up times are from 8 minutes to
24 hours. If
even longer times are desirable, extra battery cabinets or extra internal
batteries are optional.
Please note: a good rule of thumb to keep
in mind for calculating backup time for your application is "if you halve
the load, you triple the backup time of the batteries." e.g. if you use a
1000W UPS that has a full load backup time of 10 minutes, but your true rms
measured load wattage is actually only 500W, then your backup time would
actually be about 30 minutes.
The Outdoor XUPs series sine wave outdoor UPS incorporates a built-in automatic
voltage regulator to enable handling wide voltage swings without having to
exercise the batteries, which thereby extends battery life. This is an
important feature for remote locations where being so far out may
create significant voltage drop from nominal.
Line-interactive single conversion UPS topologies are utilized
as the primary choice for these units (instead of double conversion ac-dc-ac
"true on-line" UPS) due to the typical application's critical need for light weight and
as little heat throw-off from the
UPS as possible. In addition to ambient temperature, too much extra heating
from the UPS itself could otherwise potentially create an over-temperature
situation. Outdoor UPS transfer times from utility to battery power are
extremely fast, and essentially invisible to the modern switch mode power
supplies used in almost all new systems these days.
Please note: if you are an OEM/systems integrator
already utilizing your own outdoor enclosure and have enough space inside
for a wide temperature UPS, click here
for "indoor" wide temperature UPS.
Typical outdoor uninterruptible power supply applications would be:
- For CCTV
video surveillance public security operations,
to enable video detection camera views to continue during a power
outage.
- For
broadband and cellular base stations,
to protect local and wireless cellular networks from loss of transmission
during outages.
- For
remote authorization systems,
to make sure people can still get in and out when they need to.
- For
advanced traffic management systems (ATMS),
to make sure traffic control LED signals keep intersections clear.
Outdoor uninterruptible power supplies
( Click on underlined hyperlink to view full brochure/specifications )
|
|
 |
Outdoor XUPs with automatic voltage regulation
Outdoor XUPS
for extreme wide temperatures and severe outdoor environments,
these UPS and optional extra battery cabinets in IP44 (NEMA 3R) rated outdoor
enclosures offer long backup times in pole mountable, wall
mountable or pedestal mountable design. These offer line interactive
automatic voltage regulation (AVR), over/ under-voltage protection, surge
protection with heavy duty noise filtering, communications capability and
optional extended battery backup.
As remote systems tend to be customized and vary, enclosures and UPS
design will vary also. The following units are just some of the typical examples.
Outdoor
XUPs-600-A/B ~ 120V, 600VA
1 or 2.2 hours at 420W load, 8 or 16 hours at a
50W load.
Outdoor
XUPs-600AHV/BHV ~ 230V, 600VA
1 or 2.2 hours at 420W load, 8 or 16 hours at a
50W load.
Outdoor
XUPs-1000A/B ~ 120V, 420VA
1 or 2.2 hours at 420W load, 8 or 16 hours at a
50W load.
Outdoor
XUPs-1000AHV/BHV ~ 230V, 420VA
1 or 2.2 hours at 420W load, 8 or 16 hours at a
50W load. |
|
 |
Outdoor XUPs with AVR and maintenance bypass
Outdoor XUPS
with maintenance bypass and optional
automatic bypass designed for extreme mission-critical applications. With
special powder coated grey finish for a neutral blending in neutrally with the environment.
Suitable for pole mounting (or pedestal) and for extreme wide temperatures/severe outdoor
weather conditions. These UPS and optional extra battery cabinets in an IP44
(NEMA 3R) rated outdoor
enclosures offer long backup times in pole mountable, wall
mountable or pedestal mountable design. These units offer line interactive
automatic voltage regulation, over/ under-voltage protection, surge
protection with heavy duty noise filtering, communications capability,
and "hotel" capability for OEMs. Additional 24V ac output is also
available as an option. As remote systems tend to be customized and vary, enclosures and UPS
design may vary.
Outdoor
XUPs-600-6339 ~ 120V, 600VA
Includes a built-in maintenance bypass switch.
Optional auto-bypass.
40 minutes at 480W load. 120 minutes at 480W load is possible with inclusion
of the optional EXt-600-6339 extra battery cabinet. Includes
small OEM
'hotel' space for wireless, CCTV or other equipment. |
|
 |
Outdoor XUPs ~ e.g. Custom applications/OEM
Outdoor XUPS
for large project rollouts can
necessitate different battery configurations, different enclosures, battery
heaters for arctic areas, maintenance or automatic-bypass switches, etc.
Following is an example of an outdoor UPS for extreme wide temperatures and severe
weather conditions. These are
similar to the above outdoor XUPs units, come in IP44
(NEMA 3R) rated outdoor
enclosures in pole mountable (with optional pole mounting bracket), wall
mountable or pedestal mountable design. These UPS offer line-interactive
automatic voltage regulation with wide input voltage windows, over/ under-voltage protection, surge
protection with heavy duty noise filtering, communications capability,
and optional extended battery backup. Additional 24V ac output is also
available as an option.
As remote systems tend to be customized, enclosures and UPS
design may vary per your application.
Outdoor
XUPs-600C ~ 120V, 600VA
Configured to provide 11 hours @ 400W load.
Outdoor
XUPs-600CHV ~ 230V, 420VA
OEM battery-less version configured for 11 hours at 420W load. |
|
 |
Outdoor UPs for heavy-duty environments
Ferroresonant constant voltage transformer output
Ferroresonant
constant voltage regulating isolation transformer no-break UPS system in an outdoor
rated NEMA 3R enclosure. This is a heavy duty
uninterruptible power system with a constant voltage pure sine wave output
intended for areas needing the best surge protection and +/-3% automatic
voltage regulation as well as backup. Batteries are rated for extreme
wide temperature range.
As remote systems tend to be customized and vary considerably, enclosures
and UPS design will vary also.
Outdoor UPs-10000-16000-21000 ~ 120V, 1kVA, 1.6kVA &
2.1kVA
(230V models available). |
|
 |
UPs-400Wtb
UPs with wide temperature battery for extreme climate conditions and for use
inside existing OEM outdoor enclosures. Battery backup with wide temperature
batteries, communications capability and good surge protection. This unit
also has the flexibility of adding extra battery cabinets to it for long
backup times. This unit is designed to be a low-cost wide temp UPS, and does
Not include automatic voltage regulation. This may or may not be an issue
for your application as some switch-mode power supplies have relatively
adequate voltage regulation for areas in developed countries with fairly
stable voltage and where outages are rare, so the benefits of longer battery
life from voltage regulation may not be as significant.
UPs-400Wtb
~ 120V, 400VA
Please note: the rack-mountable indoor XUPs-600/1000
is available without batteries for OEMs that need a wide temperature UPS
with voltage regulation and with conformal coated boards. However, the OEM
must be able to supply enough space inside their cabinet for the wide
temperature batteries and enough room to be able to make safe connections
and service them. There is also a wide temperature OEM module available,
also without batteries, for OEMs placing systems around the world and want
to source their batteries more locally. For both of the above,
click here for the single conversion UPS page.
Please call to discuss. |
|
 |
Outdoor UPs-400Conf1-2
For cost-effective outdoor UPS backup in extreme wide temperatures and outdoor environments,
these UPS and optional extra battery cabinets in IP44 (NEMA 3R) rated outdoor
enclosures offer up to 2 hours of backup time at a 250W load in a pole mounted or wall
mounted design. They also include conformal coated boards to resist moisture
incursion. These units are the least expensive of the outdoor UPS units, and
do Not include automatic voltage regulation as the XUPs or ferroresonant
units do. This may or may not be an issue for your application as some switch-mode power supplies
have relatively adequate voltage regulation for areas in developed countries
with fairly stable voltage and where outages are rare.
As remote systems tend to be customized and vary, enclosures and UPS
design may vary per your application.
Outdoor
UPs-400Conf1-2 ~ 120V, 400VA
Conf1 ~ 1 hour at 250W load. Conf2 ~ 2 hours at
a 250W load. |
|
 |
Outdoor UPs with 12vdc, 24vdc or 48vdc output
For outdoor dc powered applications up to 96 watts needing UPS backup in extreme wide temperatures and outdoor environments,
these uninterruptible power systems in an IP44 (NEMA 3R) rated outdoor
enclosures offer up to 8 hours of backup time at a 48 watts load in a pole mountable or wall
mountable design. These units have an extremely wide ac input voltage
window, heavy duty surge protection and noise filtering and offer automatic
voltage regulation suitable for underdeveloped countries
where unstable voltage and power outages are common.
Outdoor
UPs-8015 ~ 115vac input, 12vdc out, 96W: 1 hour@48W
Backup time ~ 0.4 hour at 96 watts load or 1 hour at
a 48 watts load.
Outdoor
UPs-8016 ~ 115vac input, 12vdc out, 96W: 7 hours@48W
Backup time ~ 3 hours at 96 watts load or 7 hours at
a 48 watts load.
Outdoor
UPs-8011 ~ 115vac input, 24vdc out, 96W: 2 hours@48W
Backup time ~ 1 hour at 96 watts load or 2 hours at
a 48 watts load.
Outdoor
UPs-8012 ~ 115vac input, 24vdc out, 96W: 4 hours@48W
Backup time ~ 2 hours at 96 watts load or 4 hours at
a 48 watts load.
Outdoor
UPs-8013 ~ 115vac input, 48vdc out, 96W: 4 hours@48W
Backup time ~ 2 hours at 96 watts load or 4 hours at
a 48 watts load.
Outdoor
UPs-8014 ~ 115vac input, 48vdc out, 96W: 8 hours@48W
Backup time ~ 4 hours at 96 watts load or 8 hours at
a 48 watts load. |
Indoor line-interactive
UPS systems click Here;
for double conversion on-line UPS Here .
TSi Power is also a custom
(bespoke) outdoor UPS (uninterruptible power supply) manufacturer.
For
your OEM or special outdoor UPS applications, such as adding 24vac output, please call us.
TSi Power Book of
product specifications and white papers
To download
the entire
"TSi
Power Book of Product Specifications and White Papers,"
right click
here,
and then in your dialog box > click on 'Save Link As' or
similar, then > navigate to a desired folder where you want to store
it, and then > click on 'Save'.
Please note: The book is a 252 page, 14 megabyte Adobe Acrobat .pdf file, so it may take a while to download on a
dial-up line. The book is designed with 'bookmarks' tied to it's Table of
Contents, and the 'bookmarks' also appear on the left side as you open the pdf.
So for browsing the products and spec sheets, the book is actually quite a
fast look-up resource once you have it on your desktop. |