Top navigation bar for CareBase power quality website, homepage and product specification pages focused on mission-critical power systems protection, battery backup, precision voltage regulation and redundant on-line UPS using automatic transfer switches.

The latest news and product announcements. Power/surge protection, conditioning, control, battery backup and voltage regulation products. White Papers-Articles On Understanding and Achieving High Availability & High Quality Power Double Conversion True On-Line Battery Backup - Uninterruptible Power Systems & Single Conversion UPS Outdoor UPS for Extreme Temperature/Weather Environmental Conditions In Exterior Rated NEMA Enclosures AC Automatic Transfer Switches For Redundant Power Sources or UPS Bypass AC Power Conditioners - Low-Impedance Isolation Transformer and Ferroresonant Transformers Left navigation bar for the CareBase website focusing on mission-critical power systems and surge protection, utilizing UPS, precision automatic voltage regulators, line conditioners, battery backups, automatic transfer switches, on-line outdoor UPS, surge protective devices and more.
 

CareBase
TM
 


 

Power Conditioners,
Isolation Transformers

for conditioning your ac in addition
to surge protection ~ some with PWM
precision automatic voltage regulation


Power conditioners and isolation transformers come in a variety of forms for solving many different kinds of power problems, provide surge protection, and some come with optional PWM (pulsed width modulated) automatic voltage regulation utilizing IGBT (insulated gate bipolar transistor) technology. Some are also available in outdoor rated enclosures as outdoor power conditioners. Please look at the table below, or at the more detailed descriptions further down, to determine the isolation transformer/power conditioning series you need. 
In the table, click on the hyperlink bookmark, such as 'ILc,' to go to that power conditioning series summary. If you then want more detailed specifications, click on the underlined Acrobat PDF hyperlink. If you need help, please feel free to call.
 
 

Isolation transformers table

 

 Isolation transformer features 

     Isolation transformer series

  ILc ILc-
3 ph
ILc-
Med
FLc ILc-VRp VRp-
ILc
3 ph
Out-
door
VRx
Out-
door
VRp-Ilc
  Low-impedance isolation transformer
  Medical grade UL/cUL 60601-1 design 

  Filtering and surge protection

  Overvoltage/undervoltage cutoff
  Automatic bypass
  Wide voltage input window      
  PWM precision voltage regulation        
  Ferroresonant voltage regulation

Isolation transformer series
(Click on underlined hyperlink to view full brochure / specs PDF)

120V low-impedance isolation transformer line conditioner provides noise free power conditioning with a neutral-ground bond on the output of the transformer.
ILc-1000B

ILc-1800

120V, 208V, 240V low-impedance isolation transformer line conditioner provides noise free power conditioning with a neutral-ground bond on the output of the transformer.
ILc-5500

ILc ~ single phase
These line conditioners provide the best all-round power conditioning and surge protection for sensitive electronic equipment. The integral low-impedance isolation transformer provides 100% isolation from the input ac line. The secondary neutral-to-ground bond eliminates all surge voltages between neutral and ground. Surge protection and noise filtering are superior to conventional surge protection and filtering devices.

ILc Series conditioners reduce the need for a high quality ground and a dedicated line, while eliminating interference from adjacent sources of disturbances. ILc contributes to enhanced operation, improved repeatability, fewer reboots and system lock-ups and extended operating life. In addition, a reduction in equipment down time and service costs can be expected.

Designed for situations where reliability and predictability matter to the enterprise.

Examples include: point-of-sale terminals, telecommunications equipment, file servers, routers, digital copiers, office machines, industrial controllers (PLC), automatic test equipment (ATE), laboratory analyzers and other sensitive, specialized microprocessor-based equipment.

120V single phase models include:
ILc-600B and 1000B ~ 120V, 600VA and 1000VA
ILc-1800 ~ 120V, 1800VA
ILc-2400-3600 ~ 120 volts, 2.4kVA and 3.6kVA
~

208V/220V/230V/240V single phase models include:
ILc-2400-3600 ~ 208/220/230/240V, 2.4kVA and 3.6kVA
ILc-4400-5500 ~ 208/220/230/240V, 4.4kVA and 5.5kVA

ILc-15000 ~ 208V, single phase, 15kVA
 

Three phase 120/208Y low-impedance isolation transformer line conditioner provides noise free power conditioning with a neutral-ground bond on the output of the transformer.
       ILc-15000 shown

 

ILc ~ three phase
Three phase low-impedance isolation transformer line conditioners. The integral isolation transformer provide complete isolation between the primary and secondary, and permits bonding its output neutral to ground, which completely eliminates all disturbances between neutral and ground, regardless of source. The series inductance of the isolation transformer in combination with capacitive elements and MOVs, provide superb noise filtering, as well as coordinated multi-stage surge protection in accordance with the principles of IEC-61312.3.

These are recommended for severe environments where absolute reliability is a must. Applications include: sensitive telecommunications, radio base stations (RBS)/base transmitter stations (BTS), transmission sites for backhaul (including microwave links), industrial and medical equipment, and other sensitive, specialized microprocessor-based equipment. The ILc series offers full transformer isolation with a neutral-to-ground bond, excellent surge protection and noise filtering, tolerance of frequency variations and unpredictable loads, high efficiency, quiet operation and high reliability. The ILc series comes with a limited five-year warranty. 

ILc units come in various sizes, two common international sizes are:
ILc-9000-16500 ~ 400V delta input, 230/400V wye output

Other sizes and voltages are available. Please call.

Medical isolation transformer series
(Click on underlined hyperlink to view full brochure / specs PDF)

Medical isolation transformer line conditioner provides the ultimate in low-leakage current power conditioning for hospitals and diagnostic equipment.
    ILc-1400Med4

ILc-Med ~ single phase
Hospital-grade low-impedance medical isolation transformers. As above ILc Series, but enhanced and UL Listed to UL/cUL 60601-1 (formerly UL 2601) meeting the medical grade low leakage current specifications for patient vicinity equipment applications. Other sizes are available for custom medical applications. 
ILc-1000-1400Med4 ~ 120V, 1000 and 1400 VA.

Isolation transformers with voltage regulation series
(Click on underlined hyperlink to view full brochure / specs PDF)

Precision constant voltage output ferroresonant isolation transformer line conditioner provides the ultimate in heavy-duty surge protection and power conditioning.

FLc ~ single phase
(230V models available)
. Ferroresonant voltage regulation,  Recommended for extreme environments where absolute reliability is a must. The FLc units can replace a dedicated line and reduce harmonics, while improving system performance. Applications include industrial control equipment and telephone systems, generator/UPS combinations and other types of equipment with high availability and reliability requirements. The FLc Series offers guaranteed constant output voltage via a ferroresonant transformer, full isolation with a neutral-to-ground bond, the best surge protection available, excellent noise filtering, as well as excellent reliability.

FLc-750-1000-1500 ~ 120V ~ 750, 1000 and 1500VA ~ 120V
 

Precision automatic voltage regulator with dual input/output low-impedance isolation transformer line conditioner provides the ultimate in heavy-duty single phase power conditioning.
 

ILc-VRp ~ single phase
The ILc-VRp dual range automatic precision voltage regulator with built-in low-impedance isolation transformer allows trouble-free operation of electronic equipment over a very wide ac voltage range of 120 or 240vac +/-20% found in many developing countries. Output regulation responds in less than one line cycle and corrects output voltage to +/-2.5% with 20,000 corrections per second. There is no switching of taps or otherwise a break in the power path as continuous PWM (pulse-width-modulation) switching of the primary winding of a buck-boost transformer leaves the secondary power path intact.
ILc-2000-VRp-Dual-Range ~ 120V+240V, 2000VA
 

Precision automatic voltage regulator with low-impedance isolation transformer line conditioner provides the ultimate in heavy-duty three phase power conditioning.
  VRp-ILc-16500-0338

VRp-Ilc ~ three phase
The VRp-ILc automatic precision voltage regulator with built-in low-impedance isolation transformer allows trouble-free operation of electronic equipment over a very wide mains ac voltage range of 400V +/-20% (+/-30% for short durations) found in many developing countries.

There is no switching of taps or otherwise a break in the power path thanks to continuous PWM (pulsed-width-modulation) switching of a buck-boost transformer primary winding. Outstanding voltage regulation: under normal input range of 400vac +/- 20%, output voltage per phase will be 230 vac +/-1% (47 to 63Hz). Units feature an over/under voltage cutoff, with automatic restart when ac mains voltage returns to normal (safe) condition, below 300vac or above 160vac. Failsafe: automatic bypass (even during bypass, the over/under voltage protection is active).

These units are designed for applications where absolutely safe and precisely regulated ac power is required, such as mobile communications (GSM/satellite/wireless broadband), radio base stations (RBS) /base transmitter stations (BTS), radio / TV broadcasting, transmission sites for backhaul (including microwave links) industrial process controller (PLC), medical (mobile MRI, CT) and laboratory or analytical measurement equipment.
VRp-ILc-16500-0338, 16.5kVA, 400V delta input, 230/400V wye output. Different sizes are available, please call for more information.

Outdoor isolation transformers with voltage regulation
(Click on underlined hyperlink to view full brochure / specs PDF)

Precision automatic voltage regulator with optional low-impedance isolation transformer line conditioner provides the ultimate in heavy-duty single phase outdoor power conditioning.

Outdoor VRx ~ single phase
  TSi Power’s Outdoor VRx precision PWM automatic voltage regulator with optional built-in low-impedance isolation transformer allows trouble-free operation of electronic equipment over a wide mains ac voltage range of 172 to 276V found in many developing countries. There is no switching of taps or otherwise a break in the power path thanks to continuous PWM switching of a buck-boost transformer primary winding. VRx is also designed with a fail-safe automatic bypass which enables the VRx to provide power to the load even in the event of internal failure that may otherwise result in a disruption of power to the load. VRx with optional isolation transformer provides complete isolation from the ac line, with a neutral-to-ground bond to eliminate all surge voltages between neutral and ground.
VRx-4400-0455-0460, 220/230/240V, 4.4kVA.
Other sizes are available for different voltages.

 

Three phase precision automatic voltage regulator with optional low-impedance isolation transformer line conditioner provides the ultimate in heavy-duty outdoor power conditioning.

Outdoor VRp-ILc ~ three phase
As above three phase VRp-ILc Series, but the unit comes in a specially designed outdoor rated enclosure with multiple air exhaust fans. To maximize cooling, the isolation transformer is housed in an IP23 outer enclosure. Sensitive components are housed in an IP55 inner case. Overall equivalent is to an IP44 (NEMA-3R) enclosure. The automatic bypass assures that connected equipment will not shut down, even if VRp-ILc fails. VRp-ILc is compatible with all loads as it does not switch any components in the power path. VRp-ILc’s ultra-low impedance assures stability even with the most demanding loads. The automatic overvoltage cutoff with automatic restart ensures that operation is off-line during serious overvoltage situations that could damage the system and/or load, and then restarts without intervention when the ac mains voltage returns to the normal operating range. The lightweight, high efficiency outdoor VRp-ILc is easy to install in exterior environments.
VRp-ILc-15000/30000-5339, 15kVA/30kVA, 400V delta in, 230/400V wye out

Other sizes are available for different voltages.

TSi Power is also a custom (bespoke) low-impedance isolation transformer manufacturer.
For your OEM or special applications, please call us. 

TSi Power Book of product specifications and white papers
To download the entire
"TSi Power Book of Product Specifications and White Papers," right click here, and then in your dialog box > click on 'Save Link As' or similar, then > navigate to a desired folder and then > click on 'Save'.
Please note: The book is a 252 page, 14 megabyte Adobe Acrobat .pdf file, so it may take a while to download on a dial-up line.
The book is designed with 'bookmarks' tied to it's Table of Contents, and the 'bookmarks' also appear on the left side as you open the pdf. So for browsing the products and spec sheets, the book is actually quite a fast look-up resource once you have it on your desktop.

Back to top

 

                                               CareBase ~ PO Box 2987 ~ Glenwood Springs, Colorado  81602-2987 ~ USA ~ +1 970 945 2770 ~ 800.430.2770 (USA/CAN)
                                                   Please e-mail michael.gibson@carebase.com re: questions, RFQs, applications, etc. Copyright 1988- 2006 CareBase
                                                                                                                                  Hit Counter